syscheck error with leaky bucket cache file /var/TKLC/log/syscheck/hardware_temp.cache
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-11545600221>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 and later
Information in this document applies to any platform.
Goal
Found issue during a syscheck on MP on 5.0.0-50.21.0:
ERROR: Syscheck::LBucket::getBucketFilehandle()
ERROR: Failed locking leaky bucket cache file
ERROR: FILE: /var/TKLC/log/syscheck/hardware_temp.cache
ERROR: SYS ERR: Resource temporarily unavailable
One or more module in class "hardware" FAILED
* temp: FAILURE:: MINOR::5000000000040000 -- Platform Health Check Failure
* temp: FAILURE:: The hardware temp cache bucket was locked.
* temp: FAILURE:: MINOR::5000000000040000 -- Platform Health Check Failure
* temp: FAILURE:: ...skipping test.
Solution
The error message seen is related to a race condition that can occur when syscheck is
run manually and repeatedly which can conflict with the existing syscheck daemon that is running
on the system all the time.
This race condition can occur with the following files.
/var/TKLC/log/syscheck/hardware_fan.cache
/var/TKLC/log/syscheck/hardware_psu.cache
/var/TKLC/log/syscheck/hardware_temp.cache
You can also use "alarmMgr --alarmStatus" to see alarms on the system as this would not conflict with existing daemon. This is typically a temporary error.