Technical Instruction Sure
Solution
2066368.1
:
HA Secondary Path Down
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-11523189111>
Applies to:
BNS Platform Hardware - Version DSR 5.0 and later
Information in this document applies to any platform.
Goal
Alarm ID = 31233 (HA Secondary Path Down) appeared during upgrade
Solution
This event you are seeing is normal from the condition your system is in .
At present SOAM-a is on DSR 5.0 and SOAM-b is on DSR 7.0.1
Per the upgrade document you may see the following alarms:
Servers may have a combination of the following expected alarms.
Note: Not all servers will have all alarms:
Alarm ID = 10008 (Provisioning Manually Disabled)
Alarm ID = 10075 (The server is no longer providing services because application processes have been manually stopped)
Alarm ID = 10073 (Server Group Max Allowed HA Role Warning)
Alarm ID = 32515 (Server HA Failover Inhibited)
Alarm ID = 31228 (HA Highly available server failed to receive mate heartbeats) or (Lost Communication with Mate Server)
Alarm ID = 31283 (Highly available server failed to receive mate heartbeats)
Alarm ID = 31106 (DB Merge To Parent Failure)
Alarm ID = 31107 (DB Merge From Child Failure)
Alarm ID = 31233 (HA Secondary Path Down) appeared during upgrade
Alarm ID = 31101 (DB Replication To Slave Failure)
Alarm ID = 31104 (DB Replication over SOAP has failed