Solution Type  Technical Instruction Sure

Solution  2065981.1 :   IBM LTO5 and Higher - How to Set IP Address for LAN Port  


Related Items
  • IBM LTO7 Tape Drive
  •  
  • IBM LTO5 Tape Drive
  •  
  • IBM LTO6 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Goal
Solution


Applies to:

IBM LTO6 Tape Drive - Version All Versions and later
IBM LTO7 Tape Drive - Version All Versions and later
IBM LTO5 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

In SL3000, IBM LTO6 has 2 network ports: LAN and encryption.
Encryption port answers to 10.0.0.1 using LTO VOP.
LAN port does not answer to 10.0.0.1 but Link LED is lit.
Operator panel shows N/A for IP address, netmask and gateway.

Goal

 How can I set IP address for LAN port?

Solution

The LAN port is a service port for getting drive dumps and upgrading code.

The IBM LTO6 Operator and Service guide covers how to do these functions via the Ethernet port and what the default IP address for that port is. 

The only way to change the IP address on the LAN or Service port is to connect to the drive over the data path (FC connection) and use the IBM ITDT tool.

The LTO6 documentation is here:  http://docs.oracle.com/cd/E38452_01/index.html