Goal

How to Replace an NMS (Netra Modular System) Ethernet Cable From FBS to a Switch or the Coupler Panel

Solution

CAP PROBLEM OVERVIEW:

This procedure describes how to replace cables from the FBS to the coupler panel, switch serial management ports, or switch Ethernet ports.

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:
Netra Modular System Training

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 2

FIELD ENGINEER INSTRUCTIONS

It is recommended before arriving on site to review the process in the service manual supplement as it contains graphic and additional information that is too large or too complex to fix into this text only CAP.
Reference:
  Replace an Ethernet Cable From FBS to a Switch or the Coupler Panel
  http://docs.oracle.com/cd/E59318_01/html/E59323/z40002801912209.html#scrolltoc

Tools Needed:
#3 Phillips screwdriver - recommended magnetic with 6" minimum shaft.  A 12-16" works best on this system.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

1. Follow safety and ESD precautions.

2. Remove FBS cover at the location of the failed cable.

If needed, see Replace an FBS PCB for FBS in the service manual supplement.

3. Disconnect the faulty cable.

4. Connect the replacement cable.

5. Remove the nearby FBS covers, and start laying in the replacement cable, reinstalling FBS covers as you install the cable up the frame.

6. When you have the replacement cable up to the FBS at slot 34, install the remaining FBS covers.

7. Disconnect the faulty cable from the switch or the coupler panel.

Note -  The coupler panel connection is on the side of the coupler panel that faces the front of the modular system.
If needed, See Rear Component Locations in the service manual supplement.

8. Connect the replacement cable to the switch or coupler panel.

9. Coil up any excess cable.

If needed, see:

How to Remove FBS Covers from a Netra Modular System VCAP

 OTube How to Remove FBS Covers from a Netra Modular System VCAP

 