![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2062558.1 : Moving Of M9000 System CPU Boards Without the IOU Boards Underneath
In this Document
Created from <SR 3-11462558851> Applies to:Sun SPARC Enterprise M9000-32 Server - Version All Versions and laterSun SPARC Enterprise M9000-64 Server - Version All Versions and later Sun SPARC Enterprise M8000 Server - Version All Versions and later Information in this document applies to any platform. GoalAnswer to the question on how to add an XSB from a decommissioned domain into an in-use domain without the associated I/O. SolutionRecommend using the setdcl command with the no-io option set. Example: To move the CPU/memory resource only, and not the associated I/O, from XSB's 04-0 and 05-0 from decommissioned domain#1 into domain#0 XSCF> setdcl -d 0 -s no-io=true 04 05
Check the results with showdcl -va XSCF> showdcl -va
DID LSB XSB Status No-Mem No-IO Float Cfg-policy 00 Running FRU 00 00-0 False False False 01 01-0 False False False 02 02-0 False False False 03 03-0 False False False 04 04-0 False True False <<<<< 05 05-0 False True False <<<<< The boards 04-0 and 05-0 can now be added into the domain as required. References<NOTE:1432735.1> - M4000/M5000/M8000/M9000 Servers: Domain Configuration Information and ConsiderationsAttachments This solution has no attachment |
||||||||||||||||
|