Goal

This document explains the steps to do after Receiving a BOOT APPL-Obituary Reply for Restart - found during Health Check analysis, after upgrade from R46.0.0 to R46.0.1
 

Solution

This obit happened only once and 4 days ago.

stp123 15-09-28 08:30:18 FST EAGLE5 46.0.1-65.26.26
  ------------------------------------------------------------------------
  STH: Received a BOOT APPL-Obituary reply for restart
  Card 1115 Module restart.c Line 1299 Class 0001
  Register Dump :
  EFL=00000246 CS =0008 EIP=0064dcc8 SS =0010
  EAX=02db6fbe ECX=02da14fc EDX=02d79020 EBX=00000000
  ESP=02db6fb0 EBP=02db6fc0 ESI=00000000 EDI=00000000
  DS =0010 ES =0010 FS =0010 GS =0010
  
  Stack Dump :
  [SP+1E]=0000 [SP+16]=0065 [SP+0E]=0006 [SP+06]=0000
  [SP+1C]=0008 [SP+14]=661b [SP+0C]=9020 [SP+04]=0246
  [SP+1A]=0000 [SP+12]=02db [SP+0A]=0000 [SP+02]=0000
  [SP+18]=0006 [SP+10]=6fd0 [SP+08]=0000 [SP+00]=0008
  
  User Data Dump :
  06 00 ..
  
  Report Date:15-09-24 Time:00:44:31

The “06” in the 1rst byte of the user data Dump indicates "idle timeout" which means that the idle task (which has the lowest priority in the system) has not run in ~30 seconds
This obit normally means that you have a task that is simply taking too long and not giving up the processor so that lower priority tasks can run. So the card rebooted.

As it happened only once, I would not change the card and maybe monitor this card during one month.

There is a bug from March 2015 :

Bug 20735493 - R46.2_ST:E5-OAM boots with obit restart.c Line 1305 during pre-upgrade flash

=> This is fixed in R 46.2.0-65.46.0

 