![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2059566.1 : SL8500/SL3000 How to verify if LOD or HBD card is installed
SL8500/SL3000 Identify if LOD or HBD card is installed in drive tray In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalIdentify if LOD or HBD card is installed in drive tray SolutionSL8500/SL3000 LOD and HBD Card verification
UPDATE: 12/17/2015 1. Set the Address Filter to the drive (in this case 1.1.3.1.3 If the drive was recently powered before the log snapshot has been initiated, than you will see following 2015-12-16T16:06:39.913, 1.1.3.1.2, root, default, internal, 0, trace, 3952, "From device", Data=<request sequence="117" final="true"><command>stateChangeNotice</command><parms><deviceType>driveTray</deviceType><address>1,1,3,1,2</address><seated>true</seated><fanOk>true</fanOk><tempOk>true</tempOk><faultLedOn>false</faultLedOn><drivePowerSupplyOk>true</drivePowerSupplyOk><powerSupply48vOk>true</powerSupply48vOk><fpgaVersion>53</fpgaVersion><lodTraySN>464970G+1524L20398</lodTraySN></parms></request>
This is a indication of a LOD card installed in the drive tray Attachments This solution has no attachment |
||||||||||||||
|