![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Technical Instruction Sure Solution 2055861.1 : How to Replace an Exalogic Elastic Cloud X5-2 / X6-2 Compute node internal SAS cables
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Exalogic Elastic Cloud X5-2 Hardware - Version X5 and laterExalogic Elastic Cloud X5-2 Full Rack - Version X5 and later Exalogic Elastic Cloud X5-2 Half Rack - Version X5 and later Exalogic Elastic Cloud X5-2 Quarter Rack - Version X5 and later Exalogic Elastic Cloud X5-2 Eighth Rack - Version X5 and later Information in this document applies to any platform. GoalHow to Replace an Exalogic Elastic Cloud X5-2 Compute node internal SAS cables SolutionCAP PROBLEM OVERVIEW: X5-2 Internal SAS cables Replacement
Note: If this is an Exalogic server running OVS with virtual servers, please verify customer has readied the server by moving VM's off of the server and placed the server in maintenance mode. See Document: Making an OVS Node Unavailable for vServer Placement in Exalogic Virtual Environments using EMOC (Doc ID 1551724.1)
Removing the SAS cable1. Power off the server and disconnect the power cords from the power supplies 2. Extend the server to the maintenance position 3. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis 4. Remove the server top cover 5. Remove all of the server fan modules 6. To disconnect each SAS cable from the disk backplane, press the latch on the cable connectors and pull the connectors out 7. Disconnect the SAS cables and the super capacitor cable from the internal host bus adapter (HBA)
9. Disconnect the super capacitor cable from the super capacitor 10. Carefully remove the SAS cables and the super capacitor cable from the server
Install the SAS cable1. Carefully guide SAS cables and the super capacitor cable along the side of the chassis 2. Connect the super capacitor cable to the super capacitor 3. Connect the SAS cables the super capacitor cable to the internal HBA card 4. Install the SAS cables into the disk backplane 5. Install the PCIe riser with the internal HBA card into PCIe slot 3 6. Install all of the server fan modules 7. Install the server top cover 8. Close the server fan door 9. Return the server to the normal rack position 10. Reconnect the data cables to the server and reconnect the power cords to the server power supplies 11. Power on the server
OBTAIN CUSTOMER ACCEPTANCE Oracle Server X6-2 Documentation http://docs.oracle.com/cd/E62159_01/index.html Attachments This solution has no attachment |
||||||||||||||||||
|