Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2055760.1
Update Date:2016-08-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  2055760.1 :   Database Validation Error Was Detected On MP  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Goal
Solution
References


Created from <SR 3-11261752921>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0.1 and later
Information in this document applies to any platform.

Goal

Why are we getting database validation error on MP, after configuring “Egress Throttling Group”.

Solution

This is a bug (ID 2129912) and it indicates that during ETG configuration, Rate Limiting is Disabled or not configured

References

<BUG:21299124> - ETG: MINOR DB VALIDATION ALARM WHEN RATE LIMITING IS NOT CONFIGURED

Attachments
This solution has no attachment