![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2055213.1 : SL150 - Does Tape Library Support Control and Data Path Failover
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. GoalSL150 - Does Tape Library Support Control and Data Path fail over? SolutionThe SL150 library is a unified data and control path, using a bridging (Automation Drive Interface (ADI)) for library control and data transfer According to the specs, the SL150 supports half-height HP LTO-5 or LTO-6, FC and SAS, or half-height IBM LTO-6 FC and SAS drives The half-height HP LTO 5 FC drives only have a single interface (as do the SAS ones); the HP LTO 6 FC drives have two interfaces but normally only come with a single transceiver. Not sure about the IBM LTO 6 FC drives. The picture in the SL150 Install Manual only shows a single cable from each drive. The SL150 data sheet does not mention anything about redundant data and control paths under “Availability”. Finally there’s a document on Oracle’s support site “Bridged Libraries - Netbackup SG Driver Fails to Attach to Media Changer When Solaris mpxio is Enabled which recommends disabling Solaris MPXIO (multipathing driver) to the library, therefore strongly suggesting that this library does not support multipathing. Info provided from this entry: Attachments This solution has no attachment |
||||||||||||||
|