Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2054168.1
Update Date:2016-09-28
Keywords:

Solution Type  Technical Instruction Sure

Solution  2054168.1 :   Oracle ZFS Storage Appliance: ILOM 'SYS SERVICE' value = 'On' - How to change this to 'Off'  


Related Items
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun Storage 7110 Unified Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Goal
Solution
  A Problem exists 
 
 Steps to take to evaluate the problem
 Go back to the SP
 Log back-in to the Service Processor after 2-5 minutes
 Laptop Option to connect to SP
References


Applies to:

Sun Storage 7110 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7410 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7310 Unified Storage System - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Goal

The Sun ZFS Appliance 7410 motherboard has a chipset ILOM also known as the Service Processor that stored fault events.

The service processor chip can be effected by Solaris Fault Management Architecture (FMA).

Recommendation below are the steps to clear a SYS SERVICE led from ON to OFF.

Solution

 A Problem exists 

-> show /SYS/SERVICE/

 /SYS/SERVICE

    Targets:
    Properties:
        type = Indicator
        value = On    

Steps to take to evaluate the problem

Check that all the power and temperature values are with-in a normal range and hardware values are off.

-> show -o table -level all /SYS

 

If there is a hardware value set to On, confirm in Solaris that both see the same issue before shipping hardware for repairs.

-> start /SP/console
 login to the CLI
hostname:> maintenance problems
hostname: maintenance problems> ls
if any issues clear the faults
hostname: maintenance problems> select problem-000 markrepaired
answer "y" for yes

 

If the appliance kit software is older than 2011.8.1 then open a Service Request with the NAS team to clean-up the FMA logs.

Some newer Appliance Kit Software may still have older FMA logs that were never cleaned-up after a upgrade and may also need to cleared.



If you are the NAS tech and need help please open a collab to a technical expert on the NAS team. Who will use the manual FMA repairs

Go back to the SP

key combination is    esc shift 9    to change from CLI to SP prompt

If the Appliance Kit reports the hardware ok then correct the issue in ILOM.

Example:

-> cd /SYS/MB/P1/D1
-> set clear_fault_action=true
or
-> set /SYS/MB/P1/D1 clear_fault_action=true

> reset /SP                                                                                                                      
Are you sure you want to reset /SP (y/n)? y

Log back-in to the Service Processor after 2-5 minutes

Sun(TM) Integrated Lights Out Manager                                                                                             
                                                                                                                                  
Version 2.0.2.16                                                                                                                  
                                                                                                                                  
Copyright 2007 Sun Microsystems, Inc. All rights reserved.                                                                        
Use is subject to license terms.                                                                                                  

-> show /SYS/SERVICE/                                                                                                             
                                                                                                                                  
 /SYS/SERVICE                                                                                                                     
    Targets:                                                                                                                      
                                                                                                                                  
    Properties:                                                                                                                   
        type = Indicator                                                                                                          
        value = Off                                                                                                               
                                                                                                                                  
    Commands:                                                                                                                     
        cd                                                                                                                        
        show                                                                                                                      
                                                                                                                                  
-> 

Laptop Option to connect to SP

If the customer does not have remote console setup, the option from a laptop is ...

Connect a serial cable to the RJ-45 SER MGT port on the server’s back panel and to a laptop.

Configure the terminal emulation software running on a laptop or PC to the following settings:

    8N1: eight data bits, no parity, one stop bit
    9600 baud
    No hardware of software flow control

References

<NOTE:1964897.1> - Oracle ZFS Storage Appliance: Disk showing Amber Light, but BUI displaying Green
<NOTE:1587750.1> - Sun Storage 7000 Unified Storage System: Disk remains marked as 'faulty' in hardware view, despite several replacements done. (Unable to clear FMA event)
<BUG:17723627> - REPAIRED BUT UNRESOLVED FAULTS RESURRECTED AFTER UPGRADE TO 2011.1 8.0
<BUG:15733899> - UNABLE TO CLEAR EVENT IN FMADM FAULTY
https://stbeehive.oracle.com/teamcollab/wiki/AmberRoadSupport:FMA+event+cannot+be+cleared+by+%27replaced%27%2C+%27repaired%27+or+%27acquit%27
<BUG:17948397> - APPLIANCE SAS1 DISK FAULTS NOT RESOLVED UNTIL HEAD OWNS POOL

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.