Asset ID: |
1-71-2054120.1 |
Update Date: | 2015-09-15 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2054120.1
:
Unsolicited Alarm Message (UAM) 0115 Linkset IP TPS Threshold Exceeded - False indication
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-11323044271>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 45.0 and later
Information in this document applies to any platform.
Goal
These alarms are in the Eagle STP after the upgrade to R45.0.1-64.70.35. This alarm, according to the documentation shows that it is Sigtran links, but when rept-stat-iptps command is ran, the linksets in alarm do not show in the output.
Solution
Nothing is showing in obit's or troubles. If the active MASP has not been switched yet, I would like to have that exercise performed. Please see steps below.
1) Determine the standby/active MASP and perform the steps listed below.
• rept-stat-db
• Run following on standby MASP
• init-card:loc=
2) Wait for system to come back to DUPLEX mode
• When system is back to DUPLEX mode;
• Run following command on the active MASP
• init-card:loc=
3) Wait for system to come back to DUPLEX mode and check again for UAM 0115 alarms.
• rept-stat-trbl
References
<BUG:20623952> - WRONG ALARM "LINK EXPECTED IP TPS THRESHOLD EXCEEDED"FOR SS7 E1/T1 LINK