![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2054101.1 : CT900 blade Eth5 Is Flapping running RedHat Linux 6.1
In this Document
Created from <SR 3-10455178792> Applies to:Sun Netra CT900 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalOn a CT900 blade running RH Linux 6.1 Ethernet interface eth5 is flapping (link going up/down repeatedly) Mar 20 08:50:46 host01 kernel: niu: eth5: Link is down
Mar 20 08:50:46 host01 kernel: bonding: bond0: link status definitely down for interface eth5, disabling it Mar 20 08:50:47 host01 kernel: niu: eth5: Link is up at 10Gb/sec, full duplex Mar 20 08:50:47 host01 kernel: bond0: link status definitely up for interface eth5, 10000 Mbps full duplex. Mar 20 08:51:02 host01 kernel: device eth5 entered promiscuous mode Mar 20 08:51:08 host01 kernel: device eth5 left promiscuous mode Mar 20 08:54:00 host01 kernel: bonding: bond0: link status definitely down for interface eth5, disabling it Ifconfig output shows: # ifconfig eth5
eth5 Link encap:Ethernet HWaddr 00:21:28:3C:D6:12 BROADCAST SLAVE MULTICAST MTU:1500 Metric:1 RX packets:610471 errors:24031 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:71937152 INC05BT8
SolutionTo address this issue the following was added to the /etc/sysconfig/network-scripts/ifcfg-eth5 file: BONDING_OPTS="mode=1 miimon=200 fail_over_mac=1" References<NOTE:761868.1> - Oracle Exadata Diagnostic Information required for Disk Failures and some other Hardware issues<NOTE:1437249.1> - CT900 Troubleshooting & Data Collection Cheat Sheet <NOTE:1019438.1> - How to gather data from a Sun Netra[TM] CT900 system. <NOTE:1930475.1> - How to Replace a Sun Netra Computing Blade (CP3020/3220/3250/3270) in Netra CT900 chassis <NOTE:1471371.1> - How to Replace a switch blade for Netra CT900 chassis:ATR:1471371.1:0 <BUG:20877150> - CP3240 SWITCH FLAPPING PORT ISSUES WITH CP3270 BLADES <NOTE:1547088.2> - How to Upload Files to Oracle Support <NOTE:1387761.1> - How to replace Netra CP3140/CP3240 switch blade for Netra CT900 platform/chassis Attachments This solution has no attachment |
||||||||||||||||
|