Element Management System Alarm Manager - EMSALM Disconnection, Critical Alarm Created After 50 Minutes
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
|
In this Document
Created from <SR 3-10363170551>
Applies to:
Oracle Communications EAGLE (Hardware) - Version E5-MS 45.0 and later
Tekelec
Goal
If the EMSALM terminal connection is lost between Eagle STP and the E5MS, a critical alarm is displayed about 50 minutes after the event. This is too late. Expected time should be much less.
TEST:all EMSALM Terminals blocked at STP
Test timeline:
15:36:44 UIM 1083, System Alive from STP displayed in network-event-list
15:40:00 Action all EMSALM-Teminals blocked
… 18 min !
15:58:08 WARNING: Connection failure detected on EMSALM24
15:58:08 Info : Trying to connect to EMSALM 32
15:58:19 Info : Trying to connect to EMSALM 24
… 15 min !
16:13:08 Info : Trying tio connect to EMSALM 32
16:13:08 WARNING: Connection failure detected on EMSALM24
16:13:20 Info : Trying to connect to EMSALM 24
… 15 min !
16:28:08 Info : Trying to connect to EMSALM 32
16:28:08 Alarm CRITICAL ALARM:Cannot Connect to EAGLE for receiving Alarms
16:28:19 Info : Trying to connect to EMSALM 24
… 15 min
16:43:08 CRITICAL ALARM:Cannot Connect to EAGLE for receiving Alarms
16:43:08 Info : Trying to connect to EMSALM 32
16:43:20 Info : Trying to connect to EMSALM 24
… 15 min
16:58:08 Info : Trying to connect to EMSALM 32
16:58:08 CRITICAL ALARM:Cannot Connect to EAGLE for receiving Alarms
16:58:19 Info : Trying tio connect to EMSALM 24
17:03:17 EMSALM Terminal 24 per command activated.
… 10 min
17:13:08 Info : Trying to connect to EMSALM 32
17:13:08 CRITICAL ALARM:Cannot Connect to EAGLE for receiving Alarms
17:13:19 Info : Trying to connect to EMSALM 24
17:13:47 Info: Connection established on EMSALM 24
17:13:47 Info: automatic Alarm resync started
17:15:39 Info: automatic Alarm resync completed
17:16:44 CLEAR: Fault Interface is up.
17:16:44 UIM 1083, System Alive from STP displayed again all 5 Min .
17:17:41 EMSALM Terminal 32 per command activated. ->status goes to idle
normal status of EMSALM and Alarm situation.
Solution
Perform the following steps:
1. cat /Tekelec/WebNMS/conf/tekelec/fault.properties
2. Check for IS_ALIVE_INTERVAL in this file
3. If it is set to 15, change it to 5
4. Restart the E5MS application
5. Test the IPSM removal after this. It should take the critical alarm to appear in approximately 15 minutes.
References
<BUG:20962637> - SR: SYSTEM IS NOT ALARMING AFTER IS_ALIVE_INTERVAL IS REACHED