Solution Type Technical Instruction Sure Solution 2053082.1 : How to Replace an NMS (Netra Modular System) FBS Power Cord
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Netra Modular System - Version All Versions and laterInformation in this document applies to any platform. GoalHow to Replace an NMS (Netra Modular System) FBS Power Cord SolutionCAP PROBLEM OVERVIEW: It is recommended before arriving on site to review the process in the service manual supplement as it contains graphic and additional information that is too large or too complex to fix into this text only CAP. Tools Needed: TABLE: FBS Power Cord Replacement List Using the table below, verify the replacement power cord is the correct length, then perform these steps. Note – Replacement cords are available in short and long lengths. Slot With Failed FBS Cord Remove Node and Rail From Slot Replace With FBS Power Cord Length
Replace an FBS Power Cord 1. Follow safety and ESD precautions. 2. Locate the node with the faulty FBS power cord, power down the node, then pull the node out about three inches. 3. Also power down and remove the node and side rail at the applicable slot identified in the table above so you can access the socket on the PDU. 4. Disconnect the power cord from the PDU. 5. Remove the power cord from the FBS, then remove the cord completely from the modular system. 6. Install new power cord into the FBS. 7. Plug new power cord into the PDU. 8. Install the side rails and all nodes.
If needed, see: How to Remove FBS Covers from a Netra Modular System VCAP