![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2053066.1 : How to Replace an NMS (Netra Modular System) FBS PCB
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Netra Modular System - Version All Versions and laterInformation in this document applies to any platform. GoalHow to Replace an NMS (Netra Modular System) FBS PCB SolutionCAP PROBLEM OVERVIEW: Identify faulty FBS PCB (also known as FBN) location with diagnostics. DISPATCH INSTRUCTIONS It is recommended before arriving on site to review the process in the service manual supplement as it contains graphic and additional information that is too large or too complex to fix into this text only CAP. Tools Needed: WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : 1. Follow safety and ESD precautions. 2. From the front, locate the node corresponding to the location of the FBS PCB you are replacing. Either slide the node out about 3-4 inches, or remove the node completely. 3. From the rear of the modular system: 4. Install the node into the corresponding slot. 5. Use the system management software to configure the PCB and boot the node (i.e. use mgmt. sw to power on the node) 6. Reboot the FMM If needed, see: How to Remove FBS Covers from a Netra Modular System VCAP
Attachments This solution has no attachment |
||||||||||||||
|