Solution Type  Technical Instruction Sure

Solution  2053066.1 :   How to Replace an NMS (Netra Modular System) FBS PCB  


Related Items
  • Netra Modular System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: CAP document

Applies to:

Netra Modular System - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace an NMS (Netra Modular System) FBS PCB

Solution

CAP PROBLEM OVERVIEW:

Identify faulty FBS PCB (also known as FBN) location with diagnostics.
If the FBS PCB fault cannot be corrected, replace the FBS PCB as follows.
The PCB is a unit within the FBS that gets replaced when there is a fault.

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:
Netra Modular System Training

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 2

FIELD ENGINEER INSTRUCTIONS

It is recommended before arriving on site to review the process in the service manual supplement as it contains graphic and additional information that is too large or too complex to fix into this text only CAP.
Reference:
  Replace an FBS PCB
  http://docs.oracle.com/cd/E59318_01/html/E59323/z40003001905664.html#scrolltoc

Tools Needed:
#1 Phillips screwdriver -- Needed if you are unable to loosen the tool-less thumbscrews that hold the FBN into the FSB.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

1. Follow safety and ESD precautions.

2. From the front, locate the node corresponding to the location of the FBS PCB you are replacing. Either slide the node out about 3-4 inches, or remove the node completely.

3. From the rear of the modular system:
  a. Remove the FBS cover.
  b. Disconnect the cables that are connected to the PCB.
  c. Loosen the two thumb screws on the PCB.
  d. Remove the PCB.
  e. Install the replacement PCB.
  f. Tighten the two thumb screws on the PCB.
  g. Connect the cables to the replacement PCB.
  h. Replace the FBS cover.

4. Install the node into the corresponding slot.

5. Use the system management software to configure the PCB and boot the node  (i.e. use mgmt. sw to power on the node)

6. Reboot the FMM

If needed, see:

How to Remove FBS Covers from a Netra Modular System VCAP

 OTube How to Remove FBS Covers from a Netra Modular System VCAP

 