Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2047847.1
Update Date:2017-09-13
Keywords:

Solution Type  Technical Instruction Sure

Solution  2047847.1 :   Fujitsu M10: Firmware for the Various Hardware Components used on Fujitsu M10  


Related Items
  • Fujitsu M10-1
  •  
  • Fujitsu M10-4S
  •  
  • Fujitsu M10-4
  •  
  • Fujitsu M10 PCI Expansion Unit
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M10
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  




Applies to:

Fujitsu M10-4 - Version All Versions and later
Fujitsu M10-4S - Version All Versions and later
Fujitsu M10 PCI Expansion Unit - Version All Versions and later
Fujitsu M10-1 - Version All Versions and later
All Platforms

Goal

The intent of this document is to provide the reader with links to required firmware for assorted components that can be used on the M10 series systems.

For information on the M10 XCP firmware see Fujitsu M10 XCP Firmware Matrix.

For information on the PCI Expansion Unit firmware see Fujitsu Expansion Unit Firmware Matrix.

 

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - M Series Servers

Solution

Steps to Follow

The following matrix identifies which firmware images are required and links to obtain them:

Hardware Component                                                          

Firmware Release

Option #

MFG Part #

Download Location

Notes

1.6TB Flash Accelerator F160 NVMe Card w/ LP Bracket RA13 P3X00 FW 7110865 7307468 M10-1 - 21683464 Requires SRU14.4 or later for firmware updates.
M10-4 - 21683470
M10-4S - 21683474
PCI Expansion Unit Use the appropriate platform patch above,
requires PCIBOX1210 or later firmware.
Oracle Flash Accelerator F320 PCIe Card SW 1.3     Patch 26758830 SW1.3, KPYAIR3Q.bin
8-Port 12Gbps SAS-3 HBA (External) 06.00.02.00 7110119 7085208

FW: 06.00.02.00

Using a firmware version less than 06.00.02.00 can result
in correctable errors causing a faulted card.
Bug 20609749
200GB / 400GB Solid State Disks ( SSD's ) 3703   7082308
7082314

M10-1  Patch 25918501
M10-4  Patch 25918550
M10-4S Patch 25918531

 See doc 2259169.1 for more information

 

Common fwupdate messages and errors:

ERROR: Could not identify host type see Document 2062123.1

Get Device ID command failed: Unknown (0x7E) - see Document 2056911.1

 

Feb 14 00:02:19 <domain_name> igb: [ID 611667 kern.warning] WARNING: igb0: regsize test fail
Feb 14 00:02:19 <domain_name> igb: [ID 611667 kern.warning] WARNING: igb1: regsize test fail
Feb 14 00:02:19 <domain_name> igb: [ID 611667 kern.warning] WARNING: igb2: regsize test fail
Feb 14 00:02:19 <domain_name> igb: [ID 611667 kern.warning] WARNING: igb3: regsize test fail
Feb 14 00:02:20 <domain_name> igb: [ID 611667 kern.warning] WARNING: igb4: ioctl 82576 map not kawela
Feb 14 00:02:20 <domain_name> igb: [ID 611667 kern.warning] WARNING: igb5: ioctl 82576 map not kawela
Feb 14 00:02:20 <domain_name> igb: [ID 611667 kern.warning] WARNING: igb6: ioctl 82576 map not kawela
Feb 14 00:02:20 <domain_name> igb: [ID 611667 kern.warning] WARNING: igb7: ioctl 82576 map not kawela

Please add you case to bug 21627635


References

<BUG:21683474> - FUJITSU M10-4S RA13 P3X00 FW
<BUG:21849217> - HMP FAILED TO UPDATE HOST PROFILE AFTER AN OS/PKG UPDATE
<NOTE:2259169.1> - Fujitsu M10-1 / M10-4 / M10-4S Disk ( SSD ): Solid State Disks Experiencing "Disconnected command timeout"
<BUG:21683470> - FUJITSU M10-4 RA13 P3X00 FW
<BUG:20609749> - 12G SAS HBA IN FAULTY STATE BECAUSE RECEIVER ERROR COUNTER EXCEEDED THRESHOLD
<NOTE:2062123.1> - Fujitsu M10-1/M10-4/M10-4S: Error: fwupdate Fails with Message "ERROR: Could not identify host type"
<BUG:21458042> - SPARC M10-X SERVERS NEED FWUPDATE SUPPORT
<NOTE:1554086.1> - Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix Information
<BUG:23094001> - FUJITSU M10 PCIBOX1210 FW
<NOTE:1924671.1> - Fujitsu M10 PCI Expansion Unit Firmware Version Matrix Information
<BUG:21683464> - FUJITSU M10-1 RA13 P3X00 FW

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback