![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Technical Instruction Sure Solution 2046098.1 : Fujitsu M10-1/M10-4/M10-4S - What HDD ( Hard Disk Drive ) or SSD ( Solid State Disk ) are Supported in My M10
In this Document
Applies to:Fujitsu M10-4 - Version All Versions and laterFujitsu M10-1 - Version All Versions and later Fujitsu M10-4S - Version All Versions and later Information in this document applies to any platform. GoalIdentifying which disk is in use on an M10 system. SolutionM10 disks can be identified from the Product Code and Firmware Revision ( bold ) areas in either format or iostat below: # format
Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c1t50000395780B32C2d0 <TOSHIBA-AL13SEB600-3702-558.91GB> /pci@8000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w50000395780b32c2,0 /dev/chassis/FUJITSU-BBEXP.500000e0e06e8bbf/02ND_HDD00/disk or iostat # iostat -En
c1t50000395780B32C2d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: TOSHIBA Product: AL13SEB600 Revision: 3702 Serial No: 44B0A0D9FW28 Size: 600.13GB <600127266816 bytes> Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 Non-Aligned Writes: 0
Approved HDDs and SSDs for Fujitsu M10 Server
Attachments This solution has no attachment |
|||||||||||||||||||||||||||||||||||||||||||||||||||
|