![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2045833.1 : Oracle ZFS Storage Appliance: Fault LED Still On - But No Faults Seen On System
In this Document
Created from <SR 3-11214106666> Applies to:Sun ZFS Storage 7320 - Version All Versions and laterSun ZFS Storage 7420 - Version All Versions and later Sun ZFS Storage 7120 - Version All Versions and later Oracle ZFS Storage ZS3-4 - Version All Versions and later Oracle ZFS Storage ZS3-2 - Version All Versions and later 7000 Appliance OS (Fishworks) No faults remain on the system - but a fault LED remains lit. GoalClear a continually lit fault LED - after making sure there are no faults remaining on the system. SolutionTo view and mark repaired the faults on the Fault Management Shell (FMA faults logged to the SP): -> start /SP/faultmgmt/shell
faultmgmtsp> fmadm faulty
faultmgmtsp> fmadm repair <UUID>
faultmgmtsp> exit
ssh to the ILOM as root ILOM user -> cd /SP/logs/event
-> set clear=true Are you sure you want to clear /SP/logs/event (y/n)? y Set 'clear' to 'true' -> reset /SP
Are you sure you want to reset /SP (y/n)? y Performing reset on /SP
Checked for currency 17-AUG-2017
Attachments This solution has no attachment |
||||||||||||||
|