![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Technical Instruction Sure Solution 2045811.1 : How to Replace an Oracle Server X5-2, X6-2 Internal SAS Cable
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Oracle Server X6-2 - Version All Versions to All Versions [Release All Releases]Oracle Server X5-2 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalHow to Replace an Oracle Server X5-2, X6-2 Internal SAS Cable. SolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: TIME ESTIMATE: 60 minutes TASK COMPLEXITY: 1 FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: PROBLEM OVERVIEW: An Oracle Server X5-2, X6-2 Internal SAS Cable needs replacement WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications and OS. Then power off the server and remove the AC power cords from the system. Removing the SAS cable1. Power off the server and disconnect the power cords from the power supplies 2. Extend the server to the maintenance position 3. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis 4. Remove the server top cover 5. Remove all of the server fan modules 6. To disconnect each SAS cable from the disk backplane, press the latch on the cable connectors and pull the connectors out 7. Disconnect the SAS cables and the super capacitor cable from the internal host bus adapter (HBA)
9. Disconnect the super capacitor cable from the super capacitor 10. Carefully remove the SAS cables and the super capacitor cable from the server
Install the SAS cable1. Carefully guide SAS cables and the super capacitor cable along the side of the chassis 2. Connect the super capacitor cable to the super capacitor 3. Connect the SAS cables the super capacitor cable to the internal HBA card 4. Install the SAS cables into the disk backplane 5. Install the PCIe riser with the internal HBA card into PCIe slot 3 6. Install all of the server fan modules 7. Install the server top cover 8. Close the server fan door 9. Return the server to the normal rack position 10. Reconnect the data cables to the server and reconnect the power cords to the server power supplies 11. Power on the server
OBTAIN CUSTOMER ACCEPTANCE Oracle Server X6-2 Documentation: Attachments This solution has no attachment |
||||||||||||||||||
|