Goal
This document lists the problems resolved by the T10000D 4.09.107 Microcode
Solution
Bug Number
FSC
Synopsis
18368824
None
Changes to T10KD Qlogic FC FW to 8.01.00. This replaces RA408104 Special build.
18435867 19172244 20312176
395B
Fix for multiple customer sites reporting 395B append perm write errors running 4.08.105 code. This replaces RB408.105 Special build.
19611834
A224
Fixes A224 SNO during IPL. Was seen intermittently in prior codes.
19815453
None
Fixes incorrect FICON interface status reported by SLC library console. Replaces RD408.105 Special build.
19898334
None
Removes support for SSL version 3.0 (Poodle vulnerability) Replaces RE408.105 Special build.
20011323
3F21 NEW
New hardware detection (rollers in the tape path) when data supports a faulty roller condition exists over consecutive mounts of different tapes this code will flag the drive as defective and requires drive replacement. No more tape mounts will be allowed and the drive will report FSC 3F21.
20170474
5535
Fixes bug in 4.08.105 where 5535 retry by library will now retry properly.
20236670
37F3
Fixes rare 37F3 PERM read errors, now those tapes will be read with new RO Firmware change 0x92 releasing in this EC. Replaces RF408.102 Special build.
20480083
329B
Fixes 329B SNO’s during write attempts. This change extends the DIA time-out value which was previously available in RK408.105 Special build.
20508881
329B DC6B
In the event that the above Fix does not successfully resolve the 329B SNO this changes the SNO into a DC6B write permanent error and eliminates the SNO.
20570193
none
Fix for VSM attached RTD port failover when the fabric link goes dark.