Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2038083.1
Update Date:2016-08-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  2038083.1 :   Diameter Signaling Router (DSR) - Duplicate ULR Message Seen On Secondary Path.  


Related Items
  • BNS Platform Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Goal
Solution


Created from <SR 3-11101151391>

Applies to:

BNS Platform Hardware - Version DSR 5.0 and later
Information in this document applies to any platform.

Goal

Why is DSR sending re-transmission messages

Solution

When the DSR is responder only a re-transmission will be generated if the following conditions exist:
The SCTP SACK Delay timer value of the far end device plus the transmission delay between the DSR and the fare end device exceeds
the value of Re-transmission Timeout Minimum (RTO.min) Value for a connection configuration set for that connection.

The best way to resolve this is to have the far end reduce the SCTP SACK timer value.
This new value plus the transmission delay value must be less then the value of RTO.min for a connection configuration set for a connection.