Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2037654.1
Update Date:2018-03-02
Keywords:

Solution Type  Technical Instruction Sure

Solution  2037654.1 :   IBM LTO - Belisarius Card Bypass Procedure  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
  • IBM LTO5 Tape Drive
  •  
  • IBM LTO6 Tape Drive
  •  
  • IBM LTO4 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

IBM LTO5 Tape Drive - Version All Versions and later
IBM LTO6 Tape Drive - Version All Versions and later
IBM LTO4 Tape Drive - Version All Versions and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

IBM LTO Belisarius Card Bypass Procedure.

Solution

Belisarius Card Bypass Procedure

To bypass the Belisarius card on an Oracle IBM LTOx Drive in a SL8500 drive tray you will need to do the following:

- Take the 2 screws off of the top drive tray cover (located at the back of the drive tray).
- Take the 4 screws off that hold the drive brick to the drive tray (2 screws per side).
- Pull the drive brick out just a little so that you can access the TTI connector on the back of the drive brick.
- Once you locate the TTI connector on the back of the drive, disconnect it from the back of the drive.
- This non twisted pair cable is still connected to the Bel card and can just be left hanging loose in the drive tray.
- Locate the twisted pair cable with heat shrink tubing on it that is connected to the HBD card.
- Follow this twisted pair cable to the front of the drive tray and locate where it is plugged into the Belisarius card.
- Once located disconnect the twisted pair cable from the Belisarius card and connect it to the back of the drive brick.

This will now leave the Bel card bypassed and the library will be communicating directly to the drive.

Note: Refer to the attached procedure to see associated pictures to the procedure above.