Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2032810.1
Update Date:2017-05-18
Keywords:

Solution Type  Technical Instruction Sure

Solution  2032810.1 :   SL150 - 2.50 Firmware Fixes  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Goal

 SL150 - 2.50 Firmware Fixes.

Solution

The 2.50 code release contains the following fixes:

- The health codes that callout a specific module have been updated to read Module 1 (for the base module) and Module 2 (for the 1st expansion module).  This will help to clear up confusion on which module the failure occurred on and if a replacement is needed which module should be replaced.

- The actions for the 9135 fault code have been reworded to “Check for robot motion/obstructions. Verify robot latch is unlocked. Check base module locate sensor. Inspect/replace base module chassis or robot“.  This will help our customers to hopefully do some troubleshooting up front before replacing hardware that might not need to be replaced and could cause further more serious issues.

- A new fault code 9093 has been added for a serial number mismatch.  The serial number mismatch is caused when any 2 of the 3 mirrored S/N parts (Robot, Base Module Chassis, and OP Panel) are replaced at the same time during a successful power up.  In the past this has caused either a 9081 fault code (pre-2.25 code) or a 9999 fault code (2.25 code).  So it wasn’t clear what the issue was until you looked into the SL150 logs.

- Fault Code 9043 is no longer displayed when the library is rebooted with a USB cable disconnected. One of the new fault codes specific to the module that is no longer connected is displayed with the correct component list and recommendations.

- A fix was put in for wavy lines that were seen with the new Display Tech OP Panel.

- A fix was put in for the SL150 reporting false Power Supply faults with a fault code of 9003.

- A fix was put in place for the inability to use the Web GUI and Local OP Panel if the USB cable to a KLE controller card is disconnected.

- You can generate and retrieve the service bundle from the SL150 as long as you can get into the Web GUI.  There were failures before on the SL150 where you could get into the Web GUI but you weren’t able to access the “Service” tab and thus couldn’t generate or retrieve a service bundle.  With 2.50 as long as you can get into the Web GUI the “Service” tab should be available and thus the ability to generate and retrieve a service bundle from the SL150.