Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2032345.1
Update Date:2017-06-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  2032345.1 :   How To Modify The MTU Size In Eagle STPs  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-10597804471>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 44.x and later
Information in this document applies to any platform.

Goal

Is it possible to modify the MTU size in Eagle STPs?

Solution

MTU is determined based on path MTU discovery and controled by ICMP. The Eagle will always try to adjust back to maximum path MTU which is 1500 bytes. When the path MTU is constrained or reduced, the Eagle expects an ICMP packet from the part of the path where it is reduced to tell Eagle what the new path MTU is. In other words this is automatically adjusted by Eagle.