Diameter Signaling Router (DSR) - Why Alarm Id 22344 - Failed To Process Ingress Message: Processor Unavailable
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-11015445881>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 and later
Information in this document applies to any platform.
Goal
Why does error message 3002304 (no response from peer ) occur when a response is seen coming from peer.
Also why is info even 22344 occuring, system only has 1 MP
Solution
The peer responded with a wrong hop-by-hop id/ end-to-end id and so it was registered as no response from peer.
Also the 22344 event is seen because the DSR looks in the hop-by-hop ID for the MP ID and since it received an invalid number it registered the MP as unavailable or congested.