Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2026688.1
Update Date:2018-05-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  2026688.1 :   How to Replace an Oracle Server X5-4 Internal USB Flash Drive [VCAP]  


Related Items
  • Oracle Server X5-4
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Applies to:

Oracle Server X5-4 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to Replace an Oracle Server X5-4 Internal USB Flash Drive.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: An Oracle Server X5-4 Internal USB Flash Drive needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

 

WHAT ACTIONS ARE REQUIRED?:

1. Prepare the server for service.

Power off the server and disconnect the power cords from the power supplies.
Extend the server to the maintenance position in the rack.
Attach an anti-static wrist strap.
Remove the top cover.

2. Locate and Remove the Internal USB Flash Drive

The Internal USB Flash Drive connectors are located behind the Disk Backplane in X5-4 , see diagram below 

 

 Internal USB

To remove a USB flash drive, grasp it and pull it out of the internal USB port.
Make sure to note the USB drive's location and orientation in the USB connector so that the replacement can be reinstalled in the same location
Place the USB drive on an anti-static mat.

3. Install the replacement Internal USB Flash Drive

Remove the replacment USB Flash Drive from it's packaging and place on an anti-static mat.
Insert the USB flash drive into the internal USB port making sure to insert it into the same location and in the same orientation as the drive that was removed.
Reinstall the small plastic cover over the USB drive location.

4. Return the Server to operation

Replace the top cover
Remove any anti-static measures that were used.
Return the server to it's normal operating position within the rack.
Re-install the AC power cords and any data cables that were removed.
Power on server. Verify that the Power/OK indicator led lights steady on.
Verify that the newly installed Internal USB Flash Drive is seen by the server and that the system boots properly.

NOTE: If you have replaced the Oracle System Assistant USB flash drive, you can restore the Oracle System Assistant image onto the new USB device. For instructions, refer to the "Restore Oracle System Assistant" section of the Sun Server X5-4 Administration Guide.  https://docs.oracle.com/cd/E23161_01/html/E52424/gkvvd.html#scrolltoc

 

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:

Boot up system and verify full functionality

REFERENCE INFORMATION:

Oracle Server X5-4 Documentation:  https://docs.oracle.com/cd/E56388_01/html/E56396/index.html