Asset ID: |
1-71-2024687.1 |
Update Date: | 2017-01-04 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2024687.1
:
How Drill Down Operates in Case of Top Selection and Exclusive Lines
Related Items |
- Oracle Communications Performance Intelligence Center (PIC) Software
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
|
This document is intended to provide additional information on Drill Down functioning for the ProTraq User's Guide.
In this Document
Created from <SR 2-9400711>
Applies to:
Oracle Communications Performance Intelligence Center (PIC) Software - Version 6.6.4 and later
Information in this document applies to any platform.
Goal
Are there any exceptions in the way Drill Down from ProTrace on KPI query results is working in case of Exclusive lines or Top usage in source ProTraq configuration?
Solution
- If Drill Down is requested on the line, above which in ProTraq configuration at least one Exclusive line exist, results of such query may return more xDR than were actually used to calculate the KPI.
- If Drill Down is requested on session, which is based on Top filters, no xDRs will be returned.
References
<BUG:19091391> - [218888]PROTRAQ DRILL DOWN LIMITATIONS SHOULD BE INCLUDED IN ONLINE DOC
Attachments
This solution has no attachment