Asset ID: |
1-71-2022909.1 |
Update Date: | 2017-02-15 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2022909.1
:
User Not Replicated To Standby (or Secondary) Server
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
|
In this Document
Created from <SR 3-10766604261>
Applies to:
Oracle Communications EAGLE (Software) - Version E5-MS 45.0 and later
Tekelec
Goal
When a new user is created in Primary and then a replication is done, it is not shown in the Secondary server.
Solution
Please do the following changes.
Open the file /Tekelec/WebNMS/conf/NmsProcessesBE.conf on both the servers.
set persist_data_in_XML to false
set update_XML_during_shutdown to true
Save the file
Restart the e5msService on both the servers.
Attachments