Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2022677.1
Update Date:2018-01-05
Keywords:

Solution Type  Technical Instruction Sure

Solution  2022677.1 :   Sun Storage 7000 Unified Storage System : HOW TO make SMU use the 'right' network interface  


Related Items
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7420
  •  
  • Sun ZFS Storage 7120
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  
  • Tools>Primary Use>Configuration
  •  




In this Document
Goal
Solution
References


Created from <SR 3-10509165601>

Applies to:

Oracle ZFS Storage ZS3-BA - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-4 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Goal

Using SMU for an Oracle database, the 1Gb interface is used instead of the 10Gb interface.

 

Solution

If there are multiple interfaces, SMU will chose the non-admin interface over admin interface.

Make sure the following is true :

  • - The  1Gb interface is the only one flagged as admin.
  • - The 10Gb interface is not flagged as admin.
  • - The multihoming property is set to adaptive on ZFSSA side.

 

References

<BUG:20841592> - SMU DOES NOT SEEM TO USE THE EXPECTED NETWORK INTERFACE