Asset ID: |
1-71-2019169.1 |
Update Date: | 2017-03-23 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2019169.1
:
How to Replace a Netra Server X5-2 DVD disk
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
Applies to:
Netra Server X5-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Replace the DVD disk on an Netra Server X5-2
Solution
CAP PROBLEM OVERVIEW: DVD disk replacement
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
Netra Server X5-2 Training.
TIME ESTIMATE: 20 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Removing the DVD is a Hot Swap operation.
Notice: You will need to remove the disk in slot 5 in order to complete the replacement. The customer needs to be aware of this requirement.
1. Consider your first step.
- Notify the customer/admin, he/she are required to take the drive in slot 5 offline according to Operating System (OS) instructions. See the OS documentation.
2. Review this information and complete these prerequisites in this order.
- Remove the Filter on page 89
- Remove a Disk Drive on page 97
- Remove DVD on page 103
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Servicing the DVD Drive:
http://docs.oracle.com/cd/E53596_01/html/E53597/nbpov.z40000e2165586.html#scrolltoc
Prepare for Service:
Attach an anti-static wrist strap
1. Remove the front air filter, the slot 5 disk
- On the front air filter pinch the right and left release levers inwards, pivot the air filter forward and lift it out and away from the chassis.
- Verify that the slot 5 drive's blue Ready-to-Remove LED is lit.
- Press the release button and pivot the release lever open to the right.
- Grasp the release lever and pull the drive out of the chassis.
- Set the Disk aside in a safe location.
2. Replace the DVD drive
- Remove any media from DVD drive.
- Grasp the tab under the right side of the DVD drive and pull the tab out.
- Continue to pull the tab, so that the DVD drive slides out of the chassis.
- Set the DVD drive aside.
- Extend the tab out from the underside of the replacement DVD drive.
- Align the DVD drive to the location where it installs into the chassis. The DVD drive is oriented with the tab at the right front.
- Slide the DVD drive into the chassis.
- Press on the right side of the DVD drive to firmly seat it into the slot.
- Push the tab in under the DVD drive.
3. Reinstall slot 5 disk drive and front air filter
- Push the release button of the drive. The release lever pops out.
- Align the drive with slot 5 in the disk cage. The connector is at the rear of the drive and the release button is on the left.
- Press on the drive to slide the drive into the chassis until the release lever moves slightly inward.
- Press the release lever fully closed with a click, securing the drive into the chassis.
- Reinstall the air filter
- Set the bottom edge of the filter into the lip at the front of the chassis. The left and right release levers are facing forward.
- Pivot the filter to vertical. The release levers snap the filter into place.
4. Return the Server to operation.
- Remove any anti-static measures that were used.
- Verify that the replacement DVD functions properly.
- Verify the disk in slot 5 is functioning properly.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality.
REFERENCE INFORMATION:
Netra Server X5-2 Documentation
http://docs.oracle.com/cd/E53596_01/index.html
Oracle Integrated Lights Out Manager (ILOM) 3.2 Documentation
http://docs.oracle.com/cd/E37444_01/index.html
Attachments
This solution has no attachment