Solution
CAP PROBLEM OVERVIEW: SAS disk replacement
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 20 minutes
TASK COMPLEXITY: 0
REMOVAL/REPLACEMENT INSTRUCTIONS:
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a prerequisite but is a wise precaution.
Replacing a SAS disk is a hot swap operation. You must run commands on the server before you remove the drive.
1. Consider your first step.
- If you have not prepared for service, do so now. See “Preparing for Service”.
2. Review this information and complete these prerequisites in this order.
- Remove the Filter on page 89
- Remove a drive on page 97
WHAT ACTIONS ARE REQUIRED?:
Servicing Disk Drives:
http://docs.oracle.com/cd/E53596_01/html/E53597/nbpov.z40000e0165586.html#scrolltoc
1. Determine if you need to shut down the OS to remove the drive, and perform one of these actions.
- If the drive cannot be taken offline without shutting down the OS, follow instructions in “Power Off the Server (Power Button - Graceful)” on page 69 then go to Step #.
- If the drive can be taken offline without shutting down the OS, go to Step 5.
2. Take the drive offline according to your OS. See your OS documentation.
- Attach an anti-static wrist strap.
3. Remove the Front Air Filter
- On the front air filter pinch the right and left release levers inwards, pivot the air filter forward and lift it out and away from the chassis.
- Fully loosen the two captive screws at the rear of the top cover.
4. Replace the Faulty SAS disk drive
- Verify that the drive's blue Ready-to-Remove LED is lit.
- Press the release button and pivot the release lever open to the right.
- Grasp the release lever and pull the drive out of the chassis.
- Set the drive aside.
5. Install the replacement SAS disk drive
- Push the release button of the replacement disk drive. The release lever pops out
- Align the drive with the slot where it installs into the chassis. The connector is at the rear of the drive and the release button is on the left.
- Press on the drive to slide the drive into the chassis until the release lever moves slightly inward.
- Press the release lever fully closed with a click, securing the drive into the chassis.
6. Reinstall the Air Filter
- Set the bottom edge of the filter into the lip at the front of the chassis. The left and right release levers are facing forward.
- Pivot the filter to vertical. The release levers snap the filter into place.
7. Verify a Drive
- Access Oracle ILOM.
- Check for the presence of the drive.
-> show /SYS/DBP/HDDx/PRSNT
/SYS/DBP/HDD0/PRSNT
Targets:
Properties:
type = Entity Presence
ipmi_name = HDD0/PRSNT
class = Discrete Sensor
value = Present
alarm_status = cleared
->
where x is 0 to 7.
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
If system had been shut down, boot up system and verify full functionality.
If system is still booted, follow OS instructions to return disk to service
REFERENCE INFORMATION:
Netra Server X5-2 Documentation
http://docs.oracle.com/cd/E53596_01/index.html
Oracle Integrated Lights Out Manager (ILOM) 3.2 Documentation
http://docs.oracle.com/cd/E37444_01/index.html
Attachments