![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2019067.1 : How to prevent unnecessary HBA replacement for LP11000
In this Document
Created from <SR 3-10860821271> Applies to:Sun Fire T2000 Server - Version All Versions and laterInformation in this document applies to any platform. GoalPrevent unnessesary HBA replacement for LP11000 - for Oracle Branded and Non Oracle branded HBA SolutionBefore replacing an HBA , check the Status Leds from:
example Oracle branded HBA ======== ====================== ======== ======= ==== === === ===== ===========
If you find the following Led Pattern of a suspected LP11000 HBA: Green(blinking) <==> Yellowr(off) <==> indicates <Normal - Link Down> This is most likely NOT an HBA problem. Check the corresponding FC Cable. Check the corresponding SFP. Check the corresponding Switch port.
References<NOTE:1282491.1> - How to Identify Oracle[TM] Branded Fibre Channel (FC) HBA, CNA/FCoE and Universal 16GB HBA Cards and Their Slot LocationsAttachments This solution has no attachment |
||||||||||||||||
|