Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2019067.1
Update Date:2018-03-07
Keywords:

Solution Type  Technical Instruction Sure

Solution  2019067.1 :   How to prevent unnecessary HBA replacement for LP11000  


Related Items
  • Sun Fire T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
  •  




In this Document
Goal
Solution
References


Created from <SR 3-10860821271>

Applies to:

Sun Fire T2000 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

Prevent unnessesary HBA replacement for LP11000 - for Oracle Branded and Non Oracle branded HBA

Solution

 Before replacing an HBA , check the Status Leds from:

 

example Oracle branded HBA

========            ====================== ========  =======      ====  ===   ===  =====  ===========
FC HBAs
CODENAME               OPTION# / PART#        FRU          MODEL        SSID  BUS         xGb  PORTS  FCODE PATCH
========            ====================== ========  =======      ====  ===   ===  =====  ===========
Pyramid-E1             SG-XPCI1FC-EM4-Z       375-3398  LP11000-S    fc11    PCI-X      4Gb      1      124816

 

If you find  the following Led Pattern of a suspected LP11000 HBA:

Green(blinking) <==> Yellowr(off) <==> indicates <Normal - Link Down>

This is most likely NOT an HBA problem.

Check the corresponding FC Cable.

Check the corresponding SFP.

Check the corresponding Switch port.

 

References

<NOTE:1282491.1> - How to Identify Oracle[TM] Branded Fibre Channel (FC) HBA, CNA/FCoE and Universal 16GB HBA Cards and Their Slot Locations