Solution Type  Technical Instruction Sure

Solution  2016154.1 :   How to Check Presence of Mistral Card on PMF?  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Goal
Solution


Created from <SR 3-10781645361>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 6.6.3 to 10.1.0 [Release 6.0 to 10.0]
Information in this document applies to any platform.

Goal

 How to know if Mistral card is present in PMF-SS7 PCI slots?

Solution

In order to know, log in to PMF-SS7 with root user and execute:

dmidecode -t slot

expected output will be like below:

# dmidecode 2.12
SMBIOS 2.7 present.

Handle 0x0901, DMI type 9, 17 bytes
System Slot Information
        Designation: PCI-X Slot 1
        Type: 64-bit PCI-X
        Current Usage: In Use
        Length: Long
        ID: 1
        Characteristics:
                3.3 V is provided
                PME signal is supported
        Bus Address: 0000:07:01.0

Handle 0x0902, DMI type 9, 17 bytes
System Slot Information
        Designation: PCI-E Slot 2
        Type: x8 PCI Express
        Current Usage: Available
        Length: Long
        ID: 2
        Characteristics:
                3.3 V is provided
                PME signal is supported
        Bus Address: 0000:0b:00.0

Handle 0x0903, DMI type 9, 17 bytes
System Slot Information
        Designation: PCI-E Slot 3
        Type: x4 PCI Express
        Current Usage: Available
        Length: Long
        ID: 3
        Characteristics:
                3.3 V is provided
                PME signal is supported
        Bus Address: 0000:0f:00.0

Handle 0x0904, DMI type 9, 17 bytes
System Slot Information
        Designation: PCI-E Slot 4
        Type: x8 PCI Express
        Current Usage: Available
        Length: Long
        ID: 4
        Characteristics:
                3.3 V is provided
                PME signal is supported
        Bus Address: 0000:12:00.0

Handle 0x0905, DMI type 9, 17 bytes
System Slot Information
        Designation: PCI-E Slot 5
        Type: x4 PCI Express
        Current Usage: Available
        Length: Long
        ID: 5
        Characteristics:
                3.3 V is provided
                PME signal is supported
        Bus Address: 0000:16:00.0

Handle 0x0906, DMI type 9, 17 bytes
System Slot Information
        Designation: PCI-E Slot 6
        Type: x4 PCI Express
        Current Usage: Available
        Length: Long
        ID: 6
        Characteristics:
                3.3 V is provided
                PME signal is supported
        Bus Address: 0000:19:00.0

Check value in line "Current Usage":

  • if value is "In Use", it means card is installed in this particular slot
  • if value is "Available" for all the slots it may mean there are no cards installed or that the card installed is faulty and not communicating on the PCI bus.