Goal
Solution


Created from <SR 3-10743090291>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 45.0 and later
Tekelec

Goal

Link load is not balanced on the two SGSN linksets.
 

Solution

Check the SLKTPS value of both problematic linksets.
If one linkset has higher SLKTPS and other has less; then load cannot be balanced.
Make sure both the linksets have equal number of links that are up and have equal traffic capacity.
 