Asset ID: |
1-71-2013165.1 |
Update Date: | 2017-02-15 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2013165.1
:
Eagle :: Imbalance Load Sharing Between Two Linksets
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-10743090291>
Applies to:
Oracle Communications EAGLE (Software) - Version EAGLE 45.0 and later
Tekelec
Goal
Link load is not balanced on the two SGSN linksets.
Solution
Check the SLKTPS value of both problematic linksets.
If one linkset has higher SLKTPS and other has less; then load cannot be balanced.
Make sure both the linksets have equal number of links that are up and have equal traffic capacity.
Attachments