Solution Type Technical Instruction Sure Solution 2008266.1 : On Oracle Big Data Appliance After Memory DIMM Upgrade/Replacement it's not Showing at OS Level
In this Document
Created from <SR 3-10712712951> Applies to:Big Data Appliance X4-2 Hardware - Version All Versions to All Versions [Release All Releases]Big Data Appliance X4-2 Starter Rack - Version All Versions to All Versions [Release All Releases] Big Data Appliance X3-2 In-Rack Expansion - Version All Versions to All Versions [Release All Releases] Big Data Appliance X3-2 Starter Rack - Version All Versions to All Versions [Release All Releases] Big Data Appliance X3-2 Full Rack - Version All Versions to All Versions [Release All Releases] Linux x86-64 GoalThis document provides details about what needs to be done after memory DIMM replacement/upgrade for the memory to be recognized by the OS. SolutionAfter Upgrade or replacement of Memory DIMM, the ILOM is showing the dimms and no faults. But OS (free command) is not showing the upgraded/replaced memory. The nodes need to be rebooted after memory DIMM replacement for OS to recognize new memory. Attachments This solution has no attachment |
||||||||||||||
|