Asset ID: |
1-71-2007722.1 |
Update Date: | 2017-02-15 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2007722.1
:
Eagle :: MTP Route Showing Prohibited
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-10708526941>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 3x.x and later
Tekelec
Goal
There are three routes with different routing cost values towards MSC from STP.
The route with least routing cost shows status as PROHIBIT for non-adjacent status and Route Status
Third route is via another STP. On that STP; all linksets towards destination pointcode are up and working.
stpclli 15-05-07 12:28:56 STD EAGLE 44.0.5-64.34.26
DPCN PST SST AST
s-00000 IS-NR Allowed ACCESS
ALARM STATUS = No Alarms.
RTE COST LSN APC LS STAT NON-ADJ ROUTE STAT
1* 10 lsn1 s-06728 Allowed Allowed Allowed
2 20 lsn2 s-05953 Allowed Allowed Allowed
3 30 lsn3 s-01186 Allowed Prohibit Prohibit
Solution
Delete the route using command:
dlt-rte
Re-enter the route using command:
ent-rte
Refer to Eagle customer documentation, Commands Manual for parameters surrounding these commands.
Attachments
This solution has no attachment