Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2000240.1
Update Date:2016-06-23
Keywords:

Solution Type  Technical Instruction Sure

Solution  2000240.1 :   What VLE Microcode Is Required When Running With ELS 7.3?  


Related Items
  • Sun StorageTek Enterprise Library Software (ELS)
  •  
  • Sun StorageTek Virtual Tape Control Software (VTCS)
  •  
  • Sun Virtual Library Extension (VLE)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Library Software>SN-TP: MAINSW VTCS
  •  




In this Document
Goal
Solution


Applies to:

Sun StorageTek Virtual Tape Control Software (VTCS) - Version 7.3 and later
Sun StorageTek Enterprise Library Software (ELS) - Version 7.3 and later
Sun Virtual Library Extension (VLE) - Version 1.4 and later
IBM z/OS on System z

Goal

What microcode level is required for a VLE running with ELS 7.3?

Solution

When all hosts are running ELS 7.3 on an I level CDS and 32GB VTVs will be created, the VLE microcode needs to be 1.5.1 or higher.  If the microcode is not at the proper level, the following message will be issued:

SLS7551W STORMNGR vle_stormngr does not support VTVs greater than 4GB, global MAXVTVSZ set to 4000

For H level CDS or below, ELS 7.3 requires any VLE to be at microcode level 1.4.2 patch A3 or higher. 