![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1999730.1 : How to Check Serial Numbers of Nodes, IB Switches and PDU on Oracle Big Data Appliance
In this Document
Created from <SR 3-10566355371> Applies to:Big Data Appliance Hardware - Version All Versions and laterLinux x86-64 GoalThis document provides details about how to check serial numbers associated with nodes, IB switches and PDU on Oracle Big Data Appliance. Solution1) To find serial number of the nodes on the BDA cluster # bdaid
Server Hostname : <ServerName> Rack Serial Number : AK.... Server Serial Number : 1349NM503P Appliance Name : <RackName>
Doc ID 1299791.1 How to Determine the Serial Number of a Datacenter InfiniBand Switch 36 or QDR InfiniBand Gateway InfiniBand Switch As per HW engineer The version command shows the serial# of the SP board (i.e. only the SP) not the actual IB switch itself. IB switch serial#s are never in this format. # ssh <Switch Name/IP>
root@<Switch Name/IP>'s password: ............... You are now logged in to the root shell. It is recommended to use ILOM shell instead of root shell. All usage should be restricted to documented commands and documented config files. To view the list of documented commands, use "help" at linux prompt. # version SUN DCS gw version: 2.1.3-4 Build time: Aug 28 2013 18:16:06 FPGA version: 0x34 SP board info: Manufacturing Date: 2014.05.19 Serial Number: "NCDF30943" Hardware Revision: 0x0107 Firmware Revision: 0x0000 BIOS version: SUN0R100 BIOS date: ...........
3) To find serial number of the PDU's -> show /System/Power/Power_Supplies/Power_Supply_0
OR -> show /System/Power/Power_Supplies/Power_Supply_1
Attachments This solution has no attachment |
||||||||||||||||
|