Solution Type  Technical Instruction Sure

Solution  1999267.1 :   Issues With HW Monitoring On Thx11dbadm01.  


Related Items
  • Exadata X4-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Engineered Systems HW>SN-x64: EXADATA
  •  




In this Document
Goal
Solution
References


Created from <SR 3-10523705043>

Applies to:

Exadata X4-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

questions about OHMP
 

Solution

ipmi modules not running in the kernel

thx11dbadm01 is missing the following:

# grep ipmi ls_-laR_.dev
crw-rw----  1 root root    249,   0 Mar 20 14:07 ipmi0
lrwxrwxrwx 1 root root   16 Mar 20 14:07 ipmi:ipmi0 -> ipmi0 char/249:0
lrwxrwxrwx  1 root root    8 Mar 20 14:07 249:0 -> ../ipmi0
# pwd
/cores/3-10502163951/tds-2015-04-03/34796401_sosreport-thx12dbadm01.3-10502163951-20150403142913-fbee.tar.xz/thx12dbadm01-2015040314281428085699/sos_commands/devicemapper


# grep ipmi ls_-laR_.dev
# pwd
/cores/3-10502163951/tds-2015-04-03/34796302_sosreport-thx11dbadm01.3-10502163951-20150403141902-0713.tar.xz/thx11dbadm01-2015040314181428085114/sos_commands/devicemapper

I didn't find any other differences with the packages installed.

These kernel modules are not loaded into the kernel:

ipmi_devintf
ipmi_si  

on thx11 nodes try running:

# lsmod | grep ipmi
ipmi_poweroff           8453  0
ipmi_watchdog          17695  0
ipmi_devintf            8196  0
ipmi_si                48265  3
acpi_ipmi               3867  0
ipmi_msghandler        39598  5 ipmi_poweroff,ipmi_watchdog,ipmi_devintf,ipmi_si,acpi_ipmi

Need to install missing modules

References

<NOTE:1632787.1> - Oracle Hardware Management Pack (OHMP) is not needed on Exadata