Solution Type  Technical Instruction Sure

Solution  1996113.1 :   E5MS :: Stop Alarm Reporting To E5MS After Switch Off STP.  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  




In this Document
Goal
Solution


Created from <SR 3-10433749751>

Applies to:

Oracle Communications EAGLE (Hardware) - Version E5-MS 45.0 and later
Tekelec

Goal

Customer is going to switch off STP, he requests to stop alarms being received at the E5-MS platform from that STP but still wishes to be able to connect via the Command Management Interface (to send commands to the STP).

Solution

To Stop receiving alarms from Eagle; perform following steps:
1. In E5MS GUI Click Tools
2. In drop down menu; click Eagle Discovery
3. In Eagle Discovery; click the required STP
4. Check the IPSM Terminal used for EMSALM
5. Login to Eagle and run following command:         

chg-trm:trm=xx:all=no

  where xx is the terminal number for EMSALM found from above step

After this; no new alarms will be sent from Eagle to E5MS.