In this Document
Goal
Solution
References


Created from <SR 3-10497422920>

Applies to:

SPARC SuperCluster T4-4 - Version All Versions to All Versions [Release All Releases]
Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata X4-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exalogic Elastic Cloud X4-2 Hardware - Version X4 to X4 [Release X4]
Sun Datacenter InfiniBand Switch 36 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to change the hostname of an IB switch that is running 2.1.x
 

Solution

Original name  "infiniband36p-bur09-a-sp"  new name "newname-bur09-a-sp"

1)    -> set hostname=newname-bur09-a-sp   <<<New name specified here
          Set 'hostname' to 'newname-bur09-a-sp'

2)     -> set system_identifier=newname-bur09-a-sp.us.oracle.com
           Set 'system_identifier' to 'newname-bur09-a-sp.us.oracle.com'

3)     -> reset /SP  (Proper way to reboot an IB switch)
            Are you sure you want to reset /SP (y/n)?




Example from a test system

[root@infiniband36p-bur09-a-sp ~]# spsh

Oracle(R) Integrated Lights Out Manager
Version ILOM 3.0 r47111
Copyright (c) 2012, Oracle and/or its affiliates. All rights reserved.

-> cd /SP
/SP
-> ls  
/SP
   <snip>
   Properties:
       hostname = infiniband36p-bur09-a-sp  <<<current name
       system_contact = (none)
       system_description = Sun Datacenter InfiniBand Switch 36, ILOM v2.1.5-1, r47111
       system_identifier = infiniband36p-bur09-a-sp.us.oracle.com <<<Current System Identifier
       system_location = (none)

-> set hostname=newname-bur09-a-sp  <<<New name
Set 'hostname' to 'newname-bur09-a-sp'

-> set system_identifier=newname-bur09-a-sp.us.oracle.com
Set 'system_identifier' to 'newname-bur09-a-sp.us.oracle.com'

->reset /SP  <<<<<<<<<<<<Proper way to reboot IB switch!
Are you sure you want to reset /SP (y/n)? y
Performing reset on /SP
Broadcast message from root (Wed Sep 5 03:15:55 2012):
The system is going down for reboot NOW!
After switch comes back up we can see the system prompt and the ibswitches output reflect the new name.

[root@finiband36p-bur09-a-sp ~]# ibswitches  <<<<<CLI prompt shows new name

Switch  : 0x002128f56745a0a0 ports 36 "SUN DCS 36P QDR newname-bur09 10.152.228.224" enhanced port 0 lid 1 lmc 0<<<<<New Node Description is recognized by the SM


References: Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Datacenter InfiniBand Switch 36 Firmware Version 2.1