![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1993144.1 : How to Delete a VLAN on Sun Network 10GE Switch 72p and similar
In this Document
Created from <SR 3-10420395841> Applies to:Oracle Switch ES1-24 - Version All Versions to All Versions [Release All Releases]Sun Blade 6000 10GbE Switched 24p NEM - Version Not Applicable to Not Applicable [Release NA] Sun Network Switch - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalDeleting VLAN 10 on Sun Network 10GE Switch 72p and similar SolutionTo delete VLAN 10 and an associated interface : SEFOS# configure terminal
SEFOS(config)#no vlan 10 SEFOS(config)#no int vlan 10 SEFOS(config)# end To confirm whether it has been deleted or not: SEFOS# show vlan summary
SEFOS# show vlan
For more information see : Oracle Hardware Help Center below Switches
References<NOTE:1399483.1> - 10-Gigabit Ethernet Switches (Opus) Product Page<NOTE:1450081.2> - Information Center: Sun Network Switch Attachments This solution has no attachment |
||||||||||||||||
|