After Upgrade to DSR 5.0 "DB Replication Fault" and "Untrusted Time After Initialization" May Occur
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
- Tools>Type>Information Center
|
DSR 5.0 has changed the way NTP is configured.
This was done to timing stability reasons
If a upgrade to DSR 5.0 is preformed prior to the required NTP changes the following alarms may be generated:
"DB Replication Fault" and "Untrusted Time After Initialization" .
To clear these alarms NTP must first be configured as required by DSR 5.0.
Wait 24 hours to ensure process have a chance to clear alarms.
If system does not clear then:
To clear "Untrusted Time After Initialization"
alarm.put -e 31235 -s 5
To clear "DB Replication Fault"
alarm.put -e 31100 -s 5
In this Document
Created from <SR 3-10377260631>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 and later
Information in this document applies to any platform.
Goal
After upgrade to Diameter Signaling Router (DSR) 5.0 "DB Replication Fault" and "Untrusted Time After Initialization" occurred.
Solution
The Network Time Protocol (NTP) configuration has changed in DSR 5.0 and must configured to match this change.