Solution Type  Technical Instruction Sure

Solution  1991199.1 :   After Upgrade to DSR 5.0 "DB Replication Fault" and "Untrusted Time After Initialization" May Occur  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  
  • Tools>Type>Information Center
  •  


DSR 5.0 has changed the way NTP is configured.
This was done to timing stability reasons 
If a upgrade to DSR 5.0 is preformed prior to the required NTP changes the following alarms may be generated:
"DB Replication Fault" and "Untrusted Time After Initialization" .

To clear these alarms NTP must first be configured as required by DSR 5.0.
Wait 24 hours to ensure process have a chance to clear alarms.

If system does not clear then:

To clear "Untrusted Time After Initialization"
alarm.put -e 31235 -s 5

To clear "DB Replication Fault"
alarm.put -e 31100 -s 5

In this Document
Goal
Solution


Created from <SR 3-10377260631>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 and later
Information in this document applies to any platform.

Goal

After upgrade to Diameter Signaling Router (DSR) 5.0 "DB Replication Fault" and "Untrusted Time After Initialization" occurred.

Solution

The Network Time Protocol (NTP) configuration has changed in DSR 5.0 and must configured to match this change.