Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1990176.1
Update Date:2018-02-14
Keywords:

Solution Type  Technical Instruction Sure

Solution  1990176.1 :   How to replace the Power Supply in Cisco switch 4948  


Related Items
  • Exadata X4-2 Hardware
  •  
  • Exadata X3-2 Hardware
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • Zero Data Loss Recovery Appliance X6 Hardware
  •  
  • Cisco Catalyst 4948 Switch
  •  
  • Exadata X6-8 Hardware
  •  
  • Exadata X5-2 Hardware
  •  
  • Exadata X6-2 Hardware
  •  
  • Big Data Appliance X5-2 Hardware
  •  
  • Exalogic Elastic Cloud X5-2 Eighth Rack
  •  
  • Exadata X4-8 Hardware
  •  
  • Zero Data Loss Recovery Appliance X4 Hardware
  •  
  • Zero Data Loss Recovery Appliance X5 Hardware
  •  
  • Big Data Appliance Hardware
  •  
  • Big Data Appliance X4-2 Hardware
  •  
  • Big Data Appliance X3-2 Hardware
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Exalogic Elastic Cloud X3-2 Hardware
  •  
  • Exalogic Elastic Cloud X5-2 Quarter Rack
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Goal
Solution
References


Created from <SR 3-10224142467>

Applies to:

Exadata X4-2 Hardware - Version All Versions and later
Oracle SuperCluster M6-32 Hardware - Version All Versions and later
Oracle Exalogic Elastic Cloud X2-2 Hardware - Version X2 to X5 [Release X2 to X5]
Zero Data Loss Recovery Appliance X4 Hardware - Version All Versions and later
Zero Data Loss Recovery Appliance X5 Hardware - Version All Versions and later
Information in this document applies to any platform.

Goal

This document applies to ALL Engineered systems that include Cisco Catalyst 4948 or 4948E-F ethernet switches.

Replacing the power supply as it shows to be bad/off in "show environment" output.

( here as an example of Cisco switch 'C4948E-F'. The switch C4948 has a similar output )

 

 

exa41sw-adm01&gt;show environment
no temperature alarms


Module Sensor Temperature Status
------+--------------------------+--------------------+------------
1 air inlet 40C (58C,73C,76C) ok
1 air outlet 43C (65C,81C,84C) ok

Power Fan Inline
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C49E-300AC-F AC 300W bad/off bad/off n.a.       <<------------------- PS1 shows to be bad/off
PS2 PWR-C49E-300AC-F AC 300W good good n.a.

Power supplies needed by system : 1
Power supplies currently available : 1

Chassis Type : WS-C4948E-F

Power consumed by backplane : 0 Watts

Switch Bandwidth Utilization : 0%

Supervisor Led Color : Orange

Module 1 Status Led Color : Orange

Fantray : Good
Fantray removal timeout : 90
...........

Solution

Replacing the bad power supply.

The power supplies are hot swappable.
Cisco 4948 switch has a switch button on each power supply for power on/off individually.
So no need to power off whole Cisco switch during power supply  replacement. 

Here is details for power supply replacement on Cisco 4948 switch:

1. power switch off on the power supply you'd like to replace 
2. power cord eject
3. replace the power supply
4. power code insert 
5. power switch on
Regarding operations about step 3, here is the doc released by Cisco for your reference: 

http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins/04frus.html 

References

<NOTE:1922959.1> - One Of The Power Supplies On The Cisco (admin) Switch Shows Two Red Lights And Needs Repair

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.