Asset ID: |
1-71-1985737.1 |
Update Date: | 2018-04-10 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1985737.1
:
How to Replace an Exadata X5-2/X6-2 Compute Node PCIe Riser
Related Items |
- Zero Data Loss Recovery Appliance X6 Hardware
- Exadata X5-2 Hardware
- Exadata X5-2 Full Rack
- Exadata X5-2 Eighth Rack
- Exadata X6-2 Hardware
- Exadata X5-2 Quarter Rack
- Exadata X5-2 Half Rack
- Zero Data Loss Recovery Appliance X5 Hardware
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU replacement on Engineered system
Applies to:
Exadata X5-2 Hardware - Version All Versions and later
Exadata X5-2 Full Rack - Version All Versions and later
Exadata X5-2 Half Rack - Version All Versions and later
Exadata X5-2 Quarter Rack - Version All Versions and later
Exadata X5-2 Eighth Rack - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Replace PCIe Riser Assembly on an Exadata X5-2/X6-2 compute node.
Solution
CAP PROBLEM OVERVIEW: PCIe Card Replacement
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
Exadata Trained.
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 3-FRU
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications and OS. Then power off the server and remove the AC power cords from the system.
A data backup is not a prerequisite but is a wise precaution.
Refer to Doc: How to shutdown and startup Exadata X5 compute node and storage cells when performing hardware
maintenance (Doc ID 1982342.1)
For Extended information on this section, check MOS Note 1093890.1 Steps To Shutdown/Startup The Exadata & RDBMS
Services and Cell/Compute Nodes On An Exadata Configuration. (https://support.oracle.com/epmos/faces/ui/km
/SearchDocDisplay.jspx?id=1093890.1&type=DOCUMENT )
For a documentation reference, in the Exadata Owner’s Guide (E13874), use the section of chapter 7 titled “Non-Emergency Power
Procedures” section “Powering Off Oracle Exadata Rack” sub-section “Powering off Database Servers” available on the customer's
cell server image in the /opt/oracle/cell/doc.
http://amomv0115.us.oracle.com/archive/cd_ns/E13877_01/doc/doc.112/e13874/maintenance.htm#autoId18
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
PCIe Riser Location and Differences:
http://docs.oracle.com/cd/E41059_01/html/E48312/napsm.z40000f91037240.html#scrolltoc
1. Prepare the server for service.
- Power off the server and disconnect the power cords from the power supplies.
- Extend the server to the maintenance position in the rack.
- Attach an anti-static wrist strap.
- Remove the top cover.
2. Locate and Remove the PCIe Riser.
- There are three external PCIe slots and one internal PCIe slot in the system. They are numbered 1, 2, and 3 from left to right when you view the server from the rear. (The internal PCIe slot 4 is reserved for an internal SAS controller)
- The risers for slots 1 and 2 are different than the riser used for slot 3 and 4 and they should not be used in the incorrect slots, make sure the proper riser is used for the specific slot being replaced. The riser for slots 3 and 4 has two PCIe slots on it for use.
- Identify the PCIe riser to be replaced and if there is a PCIe card installed in the riser disconnect any external or internal cables from the card. Note the cable locations and their order to ensure they are reinstalled in their proper locations.
- For the slot 1 or 2 PCIe risers:
- Lift the green-tabbed latch on the rear of the server chassis next to the applicable PCIe slot to release the rear bracket on the PCIe card (If the riser does not have a PCIe card installed, then lift the latch to release the PCIe slot filler panel.)
- Lift the green-tabbed riser release lever on the PCIe riser with one hand and use your other hand to remove the riser from the motherboard connector.
- If there is a PCIe card installed in the riser, place the riser on an antistatic mat and note the slot in which the PCIe riser was originally installed; otherwise, set the PCIe riser aside.
- For the Slot 3 and 4 PCIe riser:
- If there is a PCIe card installed in the riser, disconnect any external or internal cables. Note - Do not disconnect the SAS cable from the internal host bus adapter card until after you have removed the riser from the server.
- Open the green-tabbed latch located on the rear of the server chassis next to PCIe slot 3 to release the rear bracket on the PCIe card (If the riser does not have a PCIe card installed in slot 3, then lift the latch to release the PCIe slot 3 filler panel.)
- To release the riser from the motherboard connector, lift the green-tabbed lease lever on the PCIe riser to the open position.
- Slide the plastic PCIe card retainer, which is mounted on the side of the chassis, toward the front of the server to release the card(s) installed in the riser.
- Grasp the riser with both hands and remove it from the server.
- Disconnect the SAS storage drive (HDD) cables from the internal HBA card installed in PCIe slot 4. Note the cable locations and their order to ensure they are reinstalled in their proper locations.
- Disconnect the super capacitor cable from the internal HBA card in slot 4.
- Place the riser and cards on an anti-static mat and make a note of the slot in which the PCIe riser was originally installed so that it can be reinstalled into it's proper slot.
3. Install the PCIe Riser.
- Remove the replacment PCIe riser from it's anti-static bag and place on an anti-static mat.
- For any PCIe cards installed in the riser insert the rear bracket that is attached to the PCIe card into the PCIe riser.
- Hold the riser in one hand and use your other hand to carefully insert the PCIe card connector into the Riser.
- Install the PCIe riser with the installed PCIe card into the server.
- For the slot 1 or 2 risers:
- Raise the green-tabbed release lever on the PCIe riser to the open (up) position.
- Making sure to install the riser into the same position from which it was removed, gently press the riser into the motherboard connector until it is seated, and then press the green-tabbed release lever on the PCIe riser to the closed (down) position.
- Close the green-tabbed latch on the rear of the server chassis next to the applicable PCIe slot to secure the rear bracket on the PCIe card to the server chassis.
- If the riser does not have a PCIe card installed, install a PCIe slot filler panel and close the green-tabbed latch to secure the filler panel.
- If there were any external cables connected to the PCIe card, reconnect them.
- For the PCIe slots 3 and 4 riser:
- Reconnect the SAS cable(s) to the internal HBA card. Be sure to connect the SAS cable for storage drives 0 through 3 (HDDs 0-3) to the connector that is farthest from the riser in which the HBA card is installed; otherwise, the server will incorrectly identify the storage drives when it is powered on.
- Reconnect the super capacitor cable to the internal HBA card in slot 4.
- Raise the green-tabbed release lever on the PCIe card to the open (up) position, and then gently press the riser into the motherboard connector until it is seated.
- Ensure that the rear bracket on the internal HBA card in PCIe slot 4 is connected to the slot in the server's chassis side wall. If the bracket is not connected, remove the riser and reposition it so that the rear bracket connects to the side wall, then gently press the riser into the motherboard connector.
- Slide the plastic PCIe card retainer that is mounted on the side of the chassis toward the back of the server to secure the card(s) installed in the riser.
- Press the green-tabbed release lever on the PCIe riser to the closed (down) position.
- To secure the rear bracket on the PCIe card to the server, close the green-tabbed latch on the rear of the server chassis.
- If the riser does not have a PCIe card installed in slot 3, install a PCIe slot filler panel and close the green-tabbed latch to secure the PCIe slot filler panel. If there is a PCIe card installed in slot 3 of the riser, reconnect any external or internal cables to the card.
4. Return the Server to operation:
- Replace the top cover.
- Remove any anti-static measures that were used.
- Return the server to it's normal operating position within the rack.
- Re-install the AC power cords and any data cables that were removed but not yet re-attached.
- Power on the server. Verify that the Power/OK indicator led lights steady on.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
Refer to doc How to shutdown and startup Exadata X5 compute node and storage cells when performing hardware
maintenance (Doc ID 1982342.1)
REFERENCE INFORMATION:
How to shutdown and startup Exadata X5 compute node and storage cells when performing hardware
maintenance (Doc ID 1982342.1)
Oracle Server X5-2 service guide: http://docs.oracle.com/cd/E41059_01/html/E48312/napsm.html#scrolltoc
Attachments
This solution has no attachment