Asset ID: |
1-71-1985701.1 |
Update Date: | 2017-07-11 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1985701.1
:
Diameter Intelligence Hub (DIH) Storage Capacity
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-10322513751>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 and later
Information in this document applies to any platform.
Goal
How do you increase the session lifetime from the default level?
Solution
- From the NSP Dashboard, go to "Centralized Configuration".
- Next, click Mediation.
- Click the + Under Sites > Hostname > IXP > Sessions
- Now a list of all sessions that are configured is displayed. Click the check box for the Reconstitution Session the Session Lifetime needs to be increased (72 Hours is default setting).
- Once the session is checked, click on the icon that has the pencil and paper on upper toolbar.
- Modify the Lifetime Hours from 72 to 168 to store 1 weeks worth of xDR's. Once changed, click Modify. "Apply Changes" banner will be displayed.
Please note that the DIH does not have a lot of space, and the session lifetimes should not exceed 1 week for this reason.
- Apply change:
Spill out the IXP and Right Click your mouse on the Hostname Link to get the menu to "Apply Changes".
- Click "Next" > "Apply Changes". After a successful save, you should see a Message stating "Successfully Applied Changes".
Attachments