Asset ID: |
1-71-1982063.1 |
Update Date: | 2016-08-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1982063.1
:
SOAM Server - Device Deployment Failed
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-9948169051>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 and later
Information in this document applies to any platform.
Goal
SOAM Device deployment failed
Solution
Commands to run on the Active NOAM server to remove the Ethernet devices from the NetworkDevice table.
irem NetworkDevice where "Device_ID=15"
irem NetworkDevice where "Device_ID=16"
irem NetworkDevice where "Device_ID=17"
irem NetworkDevice where "Device_ID=18"
irem NetworkDevice where "Device_ID=24"
irem NetworkDevice where "Device_ID=25"
irem NetworkDevice where "Device_ID=26"
irem NetworkDevice where "Device_ID=27"
The audit should recognize that the devices are removed and clear up the empty network configuration scripts.
Attachments
This solution has no attachment