![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1981625.1 : M8000 M9000 - How to update XCP firmware
In this Document
Applies to:Sun SPARC Enterprise M9000-64 Server - Version All Versions and laterSun SPARC Enterprise M9000-32 Server - Version All Versions and later Sun SPARC Enterprise M8000 Server - Version All Versions and later Information in this document applies to any platform. GoalCAP PROBLEM OVERVIEW: How to update XCP firmware To report errors or request improvements on this procedure, please go to My Oracle Support, and put a comment on Doc ID: 1981625.1
Notes:
Before starting the firmware update procedure, obtain the latest XCP firmware by downloading the appropriate patch to a location that is network-connected with the XSCF unit. At the time of writing this document, the latest version is XCP1123:
SolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE ENGINEER NEED: M8000 / M9000 Product Training/Experience TASK COMPLEXITY: 2 TIME ESTIMATE: 60 minutes (excluding possible all domain stop/start ) FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : n/a WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
The XCP firmware procedure exclusively runs on the active XSCF unit: 1. updating firmware requires a user with either platadm or fieldeng privileges, run the showuser command to confirm having appropriate privileges 2. run getflashimage, to import the new XCP firmware onto the main XSCF unit, example: getflashimage -u <username> ftp://<hostname or IP address>/<directory>/DCXCP1123.tar.gz 3. to confirm the XCP firmware image download was successful, run getflashimage -l 4. to check if firmware can be updated with domains running, run flashupdate -c check -m xcp -s 1123 5. to actually update the firmware, run flashupdate -c update -m xcp -s 1123 6. wait until the XSCF serial port or showlogs monitor output indicates the update has completed: Aug 3 07:25:48 Mx000_1-1-0 monitor_msg: SCF:XCP update has been completed (XCP version=1123) 7. To determine is all domains need to be stopped and started (using XSCF poweroff and poweron command), you can check the information in Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 XSCF Control Package (XCP) Firmware Image Software Version Matrix Information (Doc ID 1002631.1):
OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: If domains need to stopped, make sure all domains successfully get started
======================== Other info ===================== REFERENCE INFORMATION: SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide, chapter 8, http://docs.oracle.com/cd/E19415-01/E25381/E25381.pdf Attachments This solution has no attachment |
||||||||||||||||
|