Solution Type  Technical Instruction Sure

Solution  1966589.1 :   EAGLE OOT APPL-Obituary Reply For Restart-Module Ath_vxw_mgr  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-10204466688>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 44.0.5 and later
Tekelec

Goal

What to do if Obituary: Module ath_vxw_mgr.  is present?

> rtrv-obit:loc=1113

  stpt4b 15-01-28 23:08:23 EST EAGLE5 44.0.5-64.34.26
  rtrv-obit:loc=1113
  Command entered at terminal #18.
;

Command Accepted - Processing
  stpt4b 15-01-28 23:08:23 EST EAGLE5 44.0.5-64.34.26
  ------------------------------------------------------------------------
  STH: Received a BOOT APPL-Obituary reply for restart
  Card 2301 Module ath_vxw_mgr. Line 1728 Class 01c3
  Register Dump :
  EFL=00000246 CS =0008 EIP=0064d8d8 SS =0010
  EAX=02f7fc0c ECX=00000000 EDX=00000000 EBX=02f7fbfc
  ESP=02f7fbf4 EBP=02f7fc94 ESI=02f7dce4 EDI=0000000e
  DS =0010 ES =0010 FS =0010 GS =0010
  
  Stack Dump :
  [SP+1E]=02f7 [SP+16]=0001 [SP+0E]=006e [SP+06]=eeee
  [SP+1C]=c000 [SP+14]=0202 [SP+0C]=f41d [SP+04]=eeee
  [SP+1A]=0000 [SP+12]=0000 [SP+0A]=0000 [SP+02]=eeee
  [SP+18]=000e [SP+10]=0008 [SP+08]=0002 [SP+00]=eeee
  
  User Data Dump :
  02 00 00 00 1d f4 6e 00 08 00 00 00 02 02 01 00 ......n.........
  0e 00 00 00 00 c0 f7 02 30 d6 93 02 ........0...
  
  
  Report Date:15-01-27 Time:23:14:42
  ------------------------------------------------------------------------
 

Solution

Check to see if this has this obit has been produced only one time If this is the case; no action is necessary.

If this obit is appearing continuously, then un-seat and reseat the effected card once.
If the obit appears again, then you will need to replace the card with a spare and RMA the defective card.