EAGLE OOT APPL-Obituary Reply For Restart-Module Ath_vxw_mgr
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-10204466688>
Applies to:
Oracle Communications EAGLE (Software) - Version EAGLE 44.0.5 and later
Tekelec
Goal
What to do if Obituary: Module ath_vxw_mgr. is present?
> rtrv-obit:loc=1113
stpt4b 15-01-28 23:08:23 EST EAGLE5 44.0.5-64.34.26
rtrv-obit:loc=1113
Command entered at terminal #18.
;
Command Accepted - Processing
stpt4b 15-01-28 23:08:23 EST EAGLE5 44.0.5-64.34.26
------------------------------------------------------------------------
STH: Received a BOOT APPL-Obituary reply for restart
Card 2301 Module ath_vxw_mgr. Line 1728 Class 01c3
Register Dump :
EFL=00000246 CS =0008 EIP=0064d8d8 SS =0010
EAX=02f7fc0c ECX=00000000 EDX=00000000 EBX=02f7fbfc
ESP=02f7fbf4 EBP=02f7fc94 ESI=02f7dce4 EDI=0000000e
DS =0010 ES =0010 FS =0010 GS =0010
Stack Dump :
[SP+1E]=02f7 [SP+16]=0001 [SP+0E]=006e [SP+06]=eeee
[SP+1C]=c000 [SP+14]=0202 [SP+0C]=f41d [SP+04]=eeee
[SP+1A]=0000 [SP+12]=0000 [SP+0A]=0000 [SP+02]=eeee
[SP+18]=000e [SP+10]=0008 [SP+08]=0002 [SP+00]=eeee
User Data Dump :
02 00 00 00 1d f4 6e 00 08 00 00 00 02 02 01 00 ......n.........
0e 00 00 00 00 c0 f7 02 30 d6 93 02 ........0...
Report Date:15-01-27 Time:23:14:42
------------------------------------------------------------------------
Solution
Check to see if this has this obit has been produced only one time If this is the case; no action is necessary.
If this obit is appearing continuously, then un-seat and reseat the effected card once.
If the obit appears again, then you will need to replace the card with a spare and RMA the defective card.
Attachments